Disassembly of Meter
Draining Meter & Removing Counter Support
1) Drain the meter by turning it on either the inlet or outlet side.
2) Remove the counter bracket screws with a hex wrench or socket driver.
3)
Remove the drain plugs on the front and rear covers using an allen wrench. Allow more fluid to drain from the
meter.
Removing Packing Capsule
1) Remove the retaining plate using a standard flathead screwdriver.
2)
Pull out the packing gland from the meter.
WARNING
All internal pressure must be relieved to ZERO (0) pressure before beginning disassembly
of meter or components