![Total Control Systems 700-LP Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/total-control-systems/700-lp-series/700-lp-series_installation-operation-and-maintenance-manual_1138832026.webp)
Page 26
Drive Components
Removing the Dust Cover
1) Cut dust cover seal. Remove the dust cover screws with a standard flathead screwdriver.
2) Remove the dust cover, and note the setting on the micrometer.
3) Note the position of the drive gear (either above or below the packing gland pinion). .
Removing the Adjuster
1) Loosen the retaining screws using a standard flathead screwdriver.
2) Slide the retaining clip up and over to the left side.
3) From the top, remove the screws to the adjustor plate.
4) Lift adjustor out of the counter adapter.
5) Remove the adjustor drive assembly.
2
3
1
1
2
3
4
5