INTERFACE MANUAL
To use only system output signal ACK as digital output signal DO_25, for
instance, change the above bits as shown below.
1 0 0 0 0 0 0 0
To use all system output signals as the digital output signals, specify in the
following manner.
1 1 1 1 1 1 1 1
DO NOT specify zero (0; system output) for the bits of OUTPUT13 and 14.
After the above parameter has been changed, save the data, turn the power off
and on again. Otherwise, the parameter will not be operative.
0: System output signal
1: Digital output signal
Output signal cable
0: System output
1: Digital output
OUTPUT13 Reserved
(for
extending function)
DO_13
OUTPUT14 Reserved
(for
extending function)
DO_14
OUTPUT15 SV_RDY
DO_15
OUTPUT16 BT_ALM
DO_16
OUTPUT25 ACK
DO_25
OUTPUT26 TEACH
DO_26
OUTPUT27 EXTSIG
DO_27
OUTPUT28 SYS_RDY
DO_28
OUTPUT29 AUTORUN
DO_29
OUTPUT30 ALARM
DO_30
OUTPUT31 CYC_END
DO_31
OUTPUT32 LOW_ST
DO_32
STE 71367
– 64 –