2-20
T200/T200CS
Procedure 3
Diagnostic Test Program Execution Check
The FDD Diagnostic Test program is stored on the T200/T200CS Diagnostics Disk. Run the
diagnostic program. Refer to Chapter 3,
Tests and Diagnostics
, for more information about
the diagnostics test procedures.
FDD test error codes and their status names are listed in Table 2-3. Verify that the floppy
disk in the FDD is formatted correctly and the write protect tab is disabled. If any other
errors occur while the FDD diagnostics test is executing, go to Check 1.
Table 2-3 Floppy Disk Drive Error Code and Status
Code
Status
01h
Bad command
02h
Address mark not found
03h
Write protected
04h
Record not found
06h
Media removed
08h
DMA overrun error
09h
DMA boundary error
10h
CRC error
20h
FDC error
40h
Seek error
60h
FDD not drive error
80h
Time out error
EEh
Write buffer error
FFh
Data compare error
Check 1
If the following message is displayed, disable the write protect tab on the floppy
disk. If any other message appears, perform Check 2.
Write protected
Check 2
Replace the upper system board with a new one and re-start the system. If the
problem still exists, replace the lower system board.
Содержание T200
Страница 23: ...T200 T200CS 2 3 Figure 2 1 Troubleshooting Flowchart 1 2 ...
Страница 24: ...2 4 T200 T200CS Figure 2 1 Troubleshooting Flowchart 2 2 ...
Страница 82: ...3 32 T200 T200CS ...
Страница 90: ...3 40 T200 T200CS Head XX Sector XX Model name ...
Страница 153: ...T200 T200CS B 1 Appendix B Board Layout B 1 Upper System Board FOGSD2 Figure B 1 Upper System Board FOGSD2 Front ...
Страница 154: ...B 2 T200 T200CS Figure B 2 Upper System Board FOGSD2 Back ...
Страница 156: ...B 4 T200 T200CS B 2 Lower System Board FOGSU2 Figure B 3 Lower System Board FOGSU2 Front ...
Страница 157: ...T200 T200CS B 5 Figure B 4 Lower System Board FOGSU2 Back ...
Страница 170: ...T200 T200CS D 1 Appendix D USA Display Codes Table D 1 USA Display Codes ...