T200/T200CS
2-5
If the diagnostics program cannot detect an error, the problem may be intermittent. The
Running Test program should be executed several times to isolate the problem. Check the
Log Utilities function to confirm which diagnostic test detected an error(s), then perform the
appropriate procedures as follows:
1.
If an error is detected on the system test, memory test, display test, ASYNC test,
printer test, or real timer test, perform the system board troubleshooting proce-
dures in Section 2.4.
2.
If an error is detected on the keyboard test, perform the keyboard troubleshooting
procedures in Section 2.7.
3.
If an error is detected on the floppy disk test, perform the floppy disk drive
troubleshooting procedures in Section 2.5.
4.
If an error is detected on the hard disk test, perform the hard disk drive trouble-
shooting procedures in Section 2.6.
5.
If an error is detected on the tablet test, perform the tablet troubleshooting proce-
dures in Section 2.9.
Содержание T200
Страница 23: ...T200 T200CS 2 3 Figure 2 1 Troubleshooting Flowchart 1 2 ...
Страница 24: ...2 4 T200 T200CS Figure 2 1 Troubleshooting Flowchart 2 2 ...
Страница 82: ...3 32 T200 T200CS ...
Страница 90: ...3 40 T200 T200CS Head XX Sector XX Model name ...
Страница 153: ...T200 T200CS B 1 Appendix B Board Layout B 1 Upper System Board FOGSD2 Figure B 1 Upper System Board FOGSD2 Front ...
Страница 154: ...B 2 T200 T200CS Figure B 2 Upper System Board FOGSD2 Back ...
Страница 156: ...B 4 T200 T200CS B 2 Lower System Board FOGSU2 Figure B 3 Lower System Board FOGSU2 Front ...
Страница 157: ...T200 T200CS B 5 Figure B 4 Lower System Board FOGSU2 Back ...
Страница 170: ...T200 T200CS D 1 Appendix D USA Display Codes Table D 1 USA Display Codes ...