Strata CTX670 Installation
Power Considerations
3-4
Strata CTX I&M 10/02
Power Considerations
Each CTX670 Base and Expansion Cabinet houses a power supply that furnishes power to all of
the stations and some of the peripherals that interface with the cabinet (see
Table 1-60, “Strata
CTX670 Electrical Characteristics” on page 1-46
).
Reserve Power
Two or four customer-supplied 12VDC reserve batteries can be connected to the system to
maintain normal operation during a power failure (see
Table 1-63 on page 1-48
and
Table 1-60 on
page 1-46
). The batteries are kept in a highly-charged state by the standard power supply and must
be connected when the system is operating normally. Fully charged batteries must be connected
when normal AC power is available, batteries cannot be connected after/during an actual power
failure.
Underwriters’ Laboratory (UL) and local electrical codes require certain standards for connecting
commercial AC and reserve power to the CTX670 system.
Table 3-1
describes which assemblies
may be required to meet UL and local electrical code standards.
Содержание Strata CTX100
Страница 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Страница 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Страница 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Страница 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Страница 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Страница 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Страница 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...