Strata CTX670 Installation
Install Reserve Power
3-42
Strata CTX I&M 10/02
Reserve Power/AC Wiring for Three or More Cabinets (Floor
Mount)
Floor-mounted systems with three or more cabinets require a Conduit Connection Box (BCCB) to
connect reserve power cabling and AC power cabling to the system. Only a qualified electrician
can install cabling between the reserve power batteries and AC power cabling to the conduit
connection box. All other steps required to install reserve power, including installation of the
Battery Distribution Box (BBDB), can be accomplished by the normal system installer.
➤
To connect reserve power to floor-mounted systems with three or more cabinets
See
Figures 3-12
~
3-17
and follow these steps:
1. Make sure that the Conduit Connection Box is installed on the bottom base cabinet (see
Figure
3-24
). The box can be installed by the regular system installer.
2. Have a licensed electrician install conduit and battery cabling to the Conduit Connection Box
per local electrical codes. The remaining steps in this procedure can be performed by the
regular system installer (see
Figure 3-25
).
3. Install the Battery Distribution Box on the second cabinet (the cabinet directly above the
bottom cabinet), see
Figure 3-24
.
4. Plug the two Conduit Connection Box cables (coming from the left side of the BCCB box) into
the Battery Distribution Box (BBDB).
Important!
The cabinets must be connected to the (live) AC power source, and the power supply
On/Off switches set to On prior to the final step of connecting the reserve power bat-
teries to the power supplies via the BATT +/- receptacle. If the batteries are con-
nected after AC power is lost, reserve power will not function.
5. Connect cables from the (BBDB) Battery Distribution Box to the BATT +/- receptacle of
individual power supplies. BBTC2A-2M cables come with each BBDB distribution box (see
Figure 3-12
).
6. To test reserve power operation, turn off the system AC power circuit breaker with power
supply On/Off switches in the On position. The system should continue to operate without
interruption.
Note
AC/DC wiring and conduit must be installed by a licensed electrician per local electrical
code (conduit trade size is 1/2 inch).
See
“Install Reserve Power” on page 3-29
for battery specifications and wiring guidelines.
Содержание Strata CTX100
Страница 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Страница 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Страница 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Страница 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Страница 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Страница 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Страница 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...