Strata CTX Configuration
Worksheet 6: Strata CTX670 Cabinet Slot Configuration
1-36
Strata CTX I&M 10/02
Worksheet 6: Strata CTX670 Cabinet Slot
Configuration
The cabinet diagram below enables you to write in the PCBs installed in each cabinet slot. Use the
PCB placement guideline below to place PCBs in the correct slots. Fill in the PCBs that go into
each slot from the PCB quantities determined in the worksheets on the previous pages and the
information provided in this worksheet. After completing Worksheet 6, Worksheet 7 must be
completed to verify that the cabinet power factors do not exceed 85.
Notes
●
B101 (BECU)/B102 (BBCU) – Main processor slots. BEXS, BBMS, BSIS are optional subassembly PCBs (see
“CTX100 Processor Optional Subassemblies” on page 1-3
).
●
Cabinet slots marked with * provide 8 time slots; all other slots provide 16 time slots.
●
Any combination of up to 96 (basic processor) or 264 (expanded processor) RPTU and RDTU channels can be installed
in the CTX670.
●
RDTU and RPTU PCBs can only be placed in odd slots of the Base Cabinet and slots S_01, S_03, and S_05 in any
Expansion Cabinet. If 17 or more channels are used, the next highest slot adjacent to the RDTU or RPTU slot cannot be
used. Slots adjacent to 8 or 16 channel RDTU or RPTU PCBs can be used.
●
BDKU, PDKU, RDSU without Speaker OCA can be in any available slot in any cabinet.
●
BDKU, PDKU, RDSU with Speaker OCA can be in any available slots in the Base and S_01~S_06 in all Exp. Cabs.
●
BDKU/BDKS without Speaker OCA can be in any available slots in the Base and S_01~S_06 in the Expansion Cabs.
Do not install Speaker OCA telephones on BDKU/BDKS.
●
Maximum 80 digital telephones per shelf due to the Power Factor restriction.
●
For more details, see the following Placement Guidelines section.
Main Location _______________ Remote Location 1___ 2___ 3___ 4___ 5___ 6___
CTX Cabinet Slots
Base
B101
B102
S101
S102
S103
S104
S105
S106
S107
S108
PCB Type
BECU
(BEXS)
(BSIS)
BBCU
(BBMS)
Cab 2
S201
S202
S203
S204
S205
S206
S207*
S208*
S209*
S210*
PCB Type
Cab 3
S301
S302
S303
S304
S305
S306
S307*
S308*
S309*
S310*
PCB Type
Cab 4
S401
S402
S403
S404
S405
S406
S407*
S408*
S409*
S410*
PCB Type
Cab 5
S501
S502
S503
S504
S505
S506
S507*
S508*
S509*
S510*
PCB Type
Cab 6
S601
S602
S603
S604
S605
S606
S607*
S608*
S609*
S610*
PCB Type
Cab 7
S701
S702
S703
S704
S705
S706
S707*
S708*
S709*
S710*
PCB Type
Содержание Strata CTX100
Страница 16: ...Introduction Related Documents Media xii Strata CTX I M 10 02 ...
Страница 94: ...Strata CTX100 Installation Installing the CTX100 Cabinet 2 24 Strata CTX I M 10 02 ...
Страница 150: ...Strata CTX670 Installation Remote Expansion Cabinet Unit 3 56 Strata CTX I M 10 02 ...
Страница 188: ...PCB Installation Network Requirements 4 38 Strata CTX I M 10 02 ...
Страница 238: ...T1 Loop Back Testing 6 12 Strata CTX I M 10 02 ...
Страница 310: ...Station Apparatus 2000 series Telephones 8 48 Strata CTX I M 10 02 ...
Страница 342: ...Peripheral Installation Station Message Detail Recording SMDR 9 32 Strata CTX I M 10 02 ...