System & Station
Program *42-2 Secondary Clock Timing Source Reference (TBSU/RBSU/RPTU)
3-98
Strata DK40 Programming Manual Spring 1999
Program *42-2
Secondary Clock Timing Source Reference
(TBSU/RBSU/RPTU)
Program Type:
System
Initialised Default:
Initialised Data is Blank
Program *42-2 Overview
The Secondary Timing Reference is assigned with this program. This is done by entering
the slot number and where applicable the circuit number that is defined as the secondary
reference system timing source.
◆
RPTU installed - Enter the slot number (15 or 17) and always set the circuit number
to DATA=1
◆
TBSU installed - Enter the slot number (12) followed by the circuit number to be
used (1~2)
◆
RBSU installed - Enter the slot number (15~18) followed by the circuit number to
be used (1~2)
Important!
Please note only TBSU/RBSU PCB’s installed with the circuit configured for
‘TE’ operation can be used as a secondary reference system timing source.
WARNING! If the Reset key on the relevant PCB is pressed the data in this Program will
need to be reassigned.
(QWHU 3URJ 0RGH
0
6SNU
*
7 5
+ROG
0
6SNU
5
+ROG
0
6SNU
& &
+ROG
0
6SNU
& &
+ROG
Enter the RPTU, TBSU circuit number that is
defined as the secondary reference system
timing source. If a RPTU PCB is installed the
Data entered must =1
Enter the TBSU, RBSU or RPTU PCB slot number that
is defined as the secondary reference system timing
source. (Only slots 15 & 17 will support the RDAU and
RPTU PCB)
Содержание Strata AirLink DK40
Страница 1: ...Spring 1999 726 Telecommunications Division Programming Manual ...
Страница 22: ...Introduction Related Documentation xxii Strata DK40DK40 Programming Manual Spring 1999 ...
Страница 246: ...System Station Program 97 Printing Program Data through SMDR 3 188 Strata DK40 Programming Manual Spring 1999 ...
Страница 378: ...GL 8 Strata DK40 Programming Manual Spring 1999 ...