– 61 –
1H
2H
3H
4H
time
W6
Fan
speed
Time
correction
W5
W4
W3
+ 1
zone
± 0
–1
zone
(min 1)
TA-Tsc
[˚C]
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
0.0
–1.0
+6.5
+6.0
+5.5
+5.0
+4.5
–0.5
–1.5
–2.0
30 minutes
A
B
C
A
B
C
→
Time Compressor
speed
0Hz
A zone
B zone
C zone
0
–0.5
–1.0
–1.5
–2.0
–2.5
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
–9.0
–10.0
–11.0
(Room temp. – Set temp.)
TA-Tsc
[˚C]
Item
11. SLEEP MODE
operation
Operation flow and applicable data, etc.
When pushing [SLEEP MODE] button on the remote
controller, a quiet and mild operation is performed by
reducing the fan speed and the compressor speed.
<Cooling operation>
This function operates the air conditioner with the differ-
ence between the set and the room temperature as shown
in the following figure.
The time correction is performed for 8 minutes each.
<Heating operation>
Description
<Cooling operation>
1) The indoor fan speed is controlled
between W6 and W3.
The compressor speed in control
as shown in the left figure.
2) The set temperature increased
0.5°C per hour up to 2°C starting
from the set temperature when
SLEEP MODE has been received.
<Heating operation>
1) The indoor fan speed is controlled
within (W7) as maximum value.
2) The louver position is set
horizontally (Standard cooling
position) when the room
temperature comes close to the
set temperature or when 25
minutes passed after starting
SLEEP MODE operation.