– 112 –
Check
code
[20]
(Continued)
Outdoor
LED display
¥
lll
¡
l
Check and troubleshooting
(Item without special mention indicates part of outdoor unit.)
[PMV error for D room]
¥
llll
¡
[PMV error for E room]
Repair defective position.
Replace defective part.
Correct connector.
Sensor error
→
Replace.
Check outdoor P.C.B. MCC-5071
and indoor E room P.C. board.
Defect
→
Replace.
Is PMV under correct conditions?
Check temp. sensor of E room indoor unit?
TA sensor, TC sensor
YES
NO
OK
Error
Repair defective position.
Replace defective part.
Correct connector.
Sensor error
→
Replace.
Check outdoor P.C.B. MCC-5071
and indoor D room P.C. board.
Defect
→
Replace.
Is PMV under correct conditions?
Check temp. sensor of D room indoor unit?
TA sensor, TC sensor
YES
NO
OK
Error