– 133 –
Reactor cover
Reactor
relay connector
Reactor cover
Reactor
Reactor
Hooks
Partition
plate
Partition plate
No.
7
Part name
Replacement
of reactor
Procedure
1. Reactor to be attached to the inverter
assembly
1) Perform works of Detachment 1 of
1
and
4
.
2) Remove the relay connector of the reactor.
3) Remove the reactor cover.
(Truss head B tight screw Ø4 × 6, 4 pcs.)
4) Remove the reactor. (ST1T Ø4 × 6, 2 pcs.)
5) Mount a new reactor.
2. Reactor to be attached to the partition
plate
1) Perform works of Detachment 1 of
1
and
4
.
2) Remove the reactor from the partition plate.
(ST1T Ø4 × 8, 2 pcs.)
3) Mount a new reactor.
Caution to mount the inverter assembly.
When mounting the inverter assembly to the
partition plate, be sure to attach the hooks
certainly.
Remarks
Содержание RAS-5M34UAV-E
Страница 35: ... 35 4 2 Outdoor Unit RAS 5M34UAV E ...
Страница 37: ... 37 5 2 Outdoor Unit RAS 5M34UAV E POWER SUPPLY CIRCUIT ...