– 64 –
Item
Operation flow and applicable data, etc.
Description
17. Clean operation
cancel
Setting the clean operation cancel
Setting the clean operation
Indoor P.C. board
CAUTION
∗
J231 will be near the MCU so take
steps to ensure that it will not be
exposed to excessive levels of heat.
Also take care to avoid solder bridging
with the surrounding components.
NOTE
Once J231 is added, the [RESET] button
on the unit is designated for CLEAN
OPERATION (Set / Cancel), therefore
the [RESET] button can not be used for
the selection (Set / Cancel) of AUTO
RESTART function (Refer to
9-3. Auto
Restart Function
).
Add J231 of the wireless unit P.C. board assembly.
∗
This cancels the auto restart function.
Hold down the [RESET] button on the indoor unit for at
least 3 seconds but not more than 10 seconds.
The indoor unit’s buzzer emits three beeps.
This completes the clean operation cancel setting.
Hold down the [RESET] button on the indoor unit for
at least 3 seconds but not more than 10 seconds.
The indoor unit’s buzzer emits three beeps, and
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation setting.