– 61 –
Item
Operation flow and applicable data, etc.
Description
13. Air purifying
control
(Continued)
2. Description
Error is determined to have occurred
(indicated by the PURE indicator (Orange) in
the following two cases.
1) When the panel switch has been set to OFF
by the opening of the air intake grill, etc.
2) When an abnormal discharge caused by a
symptom such as the build-up of dirt has
been detected while the air purifier is ON.
NOTE
The above case 1) or 2) is deemed to have
occurred when the action concerned continues
for more than one second.
3. Operation
The sequence that PURE indicator (Orange)
is turned on are described in the following
flowchart.
1) If the air purifying error input was detected
by 5 times or under, turn on the purifier
again approx. 10 minutes after and judge it
again.
2) If the air purifying error input was detected
by 5 times or more and 1000 H timer counts
up, determine the error and turn on the
PURE indicator (Orange).
3) The FILTER indicator keeps lighting even if
the operation is stopped by the remote
controller.
The timer is stored in memory of the
microcomputer, and the operation time is
cleared by filter RESET button on the
indoor unit. (FILTER indicator goes off.)
[1]
Reset by RESET button.
[2]
Reset by RESET button or by the stop direction from the remote
controller.
NOTE
When the breaker is turned [ON] or RESET button is pushed while the
FILTER indicator is turned on, the air purifier is not turned on until the
integrated operation time of the indoor fan exceeds 1 hour after
operation start.
It is the safety measures considering an incomplete drain when electric
dust collector has been cleaned with water.
Air purifying operation
Operation indicator ON
PURE indicator (Blue) ON
Air purifier ON
Error input is detected
Air purifier OFF
Error input was detected
5 times or more
Air purifier power
estimates 1000H
PURE indicator (Orange)
ON
Approx. 10 minutes
passed from the error
input was detected.
[1]
[2]
NO
YES
YES
YES
YES
NO
NO
NO