– 130 –
7
Replacement
of reactor
1. Reactor to be attached to the inverter assembly
1)Perform works of Detachment 1 of 1 and 4.
2)Remove the relay connector of the reactor.
3)Remove the reactor cover.
(Truss head B tight screw Ø4 × 6, 4 pcs.)
4)Remove the reactor. (ST1T Ø4 × 6, 2 pcs.)
5)Mount a new reactor.
2. Reactor to be attached to the partition plate
1)Perform works of Detachment 1 of 1 and 4.
2)Remove the reactor from the partition plate.
(ST1T Ø4 × 8, 2 pcs.)
3)Mount the front panel.
∗
Caution to mount the inverter assembly.
When mounting the inverter assembly to the partition
plate, be sure to attach the hooks certainly.
No. Part name
Procedure
Remarks
Hooks
Partition
plate
Reactor cover
Reactor
relay connector
Reactor cover
Partition plate
Reactor
Reactor