– 121 –
12-1-6. Heat Exchanger
1) Perform work of Detachment
12-1-1. Removing
the Front Panel and Moving Panel
and
12-1-2.
Fixing Frame Assembly
.
2) Remove the pipe holder at the rear of the unit.
3) Remove the two fixing screws (10 mm) at the left of
the heat exchanger.
4) Remove the fixing screw of the heat exchanger
fixing holder (upper).
5) Remove the fixing screw of the heat exchanger
fixing holder (lower).
6) Release the end plate hook and the claw at the right
of the heat exchanger, pull up the heat exchanger,
and then remove the fixing holder (lower) from the
guide of the indoor unit.
Fig. 12-1-9
CAUTION
Check that the claw is engaged with the end plate hook,
and then secure the heat exchanger with screws.
12-1-7. Fan Motor
1) Perform work of Detachment
12-1-1. Removing
the Front Panel and Moving Panel
and
12-1-3. Electrical Control Cover Detached
.
2) Loosen the hexagon socket set screw of the cross
flow fan from the air discharge.
3) Remove the two fixing screws of the motor band
(right).
4) Pull the motor band (right) and the fan motor out of
the unit.
Fig. 12-1-10
CAUTION
Install the fan motor while positioning it so that the fan
motor connector comes between the positioning ribs on
the motor band (right).
Be sure to tighten the hexagon socket set screw so that it
touches the D-cut surface of the fan motor shaft.
Pipe holder
Screw
(10 mm)
Heat exchangerfixing holder
(upper)
Heat exchangerfixing holder
(lower)
Hexagon socket set screw
Fixing screws
Motor band (right)
Motor connector
Motor band (right)
Positioning ribs