Fig. 10-3-14
NOTE :
If the pipe is incorrectly, the indoor unit may
unstably be set on the wall.
After passing the connecting pipe through the pipe
hole, connect the connecting pipes to the auxiliary
pipes and wrap the facing tape around them.
Bend the connecting pipe within a radius of 30 mm.
To connect the pipe after installation of the unit
(figure)
Reference position of Liquid side and Gas side's
piping on Installation Plate.
10-3-4.
Indoor Unit Fixing
•
For detaching the indoor unit
from the installation plate, pull
the indoor unit toward you
while pushing its bottom up at
the specifi ed parts.
1.Pass the pipe through the hole in the wall and hook
the indoor unit on the installation plate at the upper
hook.
2.
Swing the indoor unit to right and left to confirm that
it
is firmly hooked up on the installation plate.
3.
While pressing the indoor unit onto the wall, hook it
at
the lower part on the installation plate. Pull the
indoor
unit toward you to confirm that it is firmly
hooked up
on the installation plate.
10-3-5. In case of Indoor unit is fixed to
Installation plate with screws
1.
Push
Installation plate
Hook
Remove 2 screw caps with flat screwdriver.
Fix them with
∅
4x10~14L, 2 screws which are
prepared at the site.
Cover screw caps as previous process.
CAUTION
•
Bind the auxiliary pipes (two) and connecting cable
with facing tape tightly. In case of leftward piping
and rear-leftward piping, bind the auxiliary pipes
(two) only with facing tape.
Carefully arrange pipes so that any pipe does not
stick out of the rear plate of the indoor unit.
Carefully
connect the auxiliary pipes and
connecting pipes to
one
another and cut off the insulating tape wound on the
connecting pipe to avoid double-taping at the joint;
moreover, seal the joint with the vinyl tape, etc.
• Since dewing results in a machine trouble, make
sure to insulate both
connecting pipes. (Use
polyethylene foam as
insulating material.)
When bending a pipe, carefully do it,
not to crush it.
•
Indoor
unit
Auxiliary
pipes
Connecting
cable
Installation
plate
•
•
Fig. 10-3-1
5
2.
3.
Fig. 10-3-1
6
326 mm
283 mm
43
mm
80°
(To the forefront of flare)
Outward form of indoor unit
R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)
Use the handle of screwdriver, etc.
Gas side
Liqu
i
d
side
1
Hook here.
Installation plate
Hook
Push
Push
Screw cap
Flat screwdriver
<How to remove>
<How to fi x>
FILE NO. SVM-17050
- 70 -
Содержание RAS-25PAVPG-ND
Страница 18: ...5 WIRING DIAGRAM FILE NO SVM 17050 18 ...