Item
10. Temporary
operation
Operation flow and applicable data, etc.
Pressing [RESET] button starts the temporary opera-
tion of [AUTO] operation. When keeping [RESET]
button pressed for 10 seconds or more, the temporary
[COOL] operation is performed.
Description
1) When pressing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pressed
for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pressed
for 10 seconds or more, “Pi” sound is
heard and the temporary [COOL]
operation starts.
4) If the filter lamp goes on, press [RESET]
button to go off the filter lamp, and then
press [RESET] button again.
5) To stop the temporary operation, press
the button again.
11. Plasma
purifier
control
This function cleaning the air in the room.
If
plasma
purifier-ON signal is received while the air
conditioner stops, the
plasma
purifier starts operation, and if it is received while the air conditioner
operates, the air conditioner and the plasma
purifier start operation.
* When the previous operation was the
operation of air condi plasma
purifier, an operation of air
condi
plasma purifier starts
by pushing AC button
on the remote
controller.
(Operation of air condi plasma
purifier is stored in memory.)
* 1
Swing is available
* 2
Fan speed is Fan Auto mode varies in
order, (M + 1)
→
(L)
→
(L–)
→
(SL).
Filter lamp ON
Press RESET button.
Did you press [RESET] button
for 3 seconds or more?
Did you press [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
Sending plasma
purifier
-ON
Operation lamp ON
Fan ON
Plasma purifier ON
Plasma purifier operation
Start of plasma purifier-ON
Operation lamp OFF
Filter-OFF
Memory position of
louver/COOL
Air condi
Plasma purifier operate
Fan stop
Plasma purifier-OFF
Louver close
All stop
Air conditioner operates
Sending plasma
purifier-OFF
1 , 2
3
4
, 4
2
Air conditioner operates
1
Air conditioner stops
operates
Air condi
Plasma
purifier
operate
*1
*2
Present status
Stop
Plasma purifier only
Air conditioner
Joint use of AC and plasma purifier
Operation button
PURE button
Air conditioner
Plasma purifier
AC operation*
Stop (All)
AC + Plasma purifier
AC + Plasma purifier
All stop
AC operation
All stop
Plasma purifier operation
AC + Plasma purifie
r
operation
Louver*1
Cooling position
Follows to AC operation
Fan speed *2
AUTO, L, L+, M, M+, H
Follows to AC operation
3
Plasma purifier
FILE NO. SVM-17050
- 40 -
Содержание RAS-25PAVPG-ND
Страница 18: ...5 WIRING DIAGRAM FILE NO SVM 17050 18 ...