10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
Before installing the wireless remote controller
•
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (- ) positions.
3 Batteries
2 Wireless remote controller
Insulate the refrigerant pipes separately
with insulation, not together.
2
3
6
4
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
1
Batteries
Flat head
wood screw
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Wireless remote control
Saddle
Extension
drain hose
(Not available,
provided by installer)
(Attach to the front panel.)
Hook
Installation
plate
Hook
52 mm or more
190 mm or more
225 mm or more
Remark :
s
Detail of accessory and installation parts can
see in the accessory sheet.
s
Some pictures might be different from the
actual parts.
6 mm thick heat resisting
polyethylene foam
Air filter
600 mm or more
600 mm or more
100 mm or more
100 mm or more
600 mm or more
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
The
fl are connection should be installed
outdoors.
Shield pipe
Bush body
FILE NO. SVM-17050