CAUTION
A high voltage (equivalent to the supply voltage) is also energized to ground through the
sensors, PMV and other low-voltage circuits. The sensor leads and other wires are covered
with insulated tubes for protection. Nevertheless, care must be taken to ensure that these
wires are not pinched.
Take sufficient care to avoid directly touching any of the circuit parts without first turning off
the power.
At times such as when the circuit board is to be replaced, place the circuit board assembly in
a vertical position.
Laying the board flat on an electrically conductive object (such as the top panel of the air conditioner's
outdoor unit) while a charge is still retained by the electrolytic capacitors of the inverter's main circuit may
cause short-circuiting between the electrolytic capacitors and secondary circuit components and result in
damage to the components.
Fig. 11-3
(
RAS-05,07
,10,13
T
AVG-
E
E
)
Fig. 11-4
(RAS-16,18
T
AV
G
-
E
E
)
Fig. 11-
2
Do NOT lay the circuit board assembly flat.
RAS-16,18
T
AV
G
-
E
E
FILE NO. SVM-19040