10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and
(-) po
sitions.
3 Batteries
2 Wireless remote controller
AC
L
Right
Rear
right
Rear
left
Bottom
right
3
Batteries
6
4
Flat head
wood screw
Remote control
holder
Wireless remote control
Air filter
Hook
Hook
For the rear left, bottom left and left piping
Installation
plate
1
(Attach to the front panel.)
Shield pipe
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension drain hose
(Not available, provided
by installer)
300 mm or more
300 mm or more
65 mm or more
2
C mm or more
E mm or more
F mm or more
D mm or more
C mm or more
Wall
Cut out a piece of SPACER from indoor
unit packaging box, roll it and insert
between the indoor unit and wall to tilt
the indoor unit for better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Do not allow the drain hose to get slack.
Left
Bottom left
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
RAS-05, 07, 10, 13TAVG-EE RAS-16, 18TAVG-EE
C
600
600
D
400
600
E
45
100
F
100
100
FILE NO. SVM-19040
- 58 -
Содержание RAS-16TAVG-EE
Страница 19: ...4 2 Outdoor Unit RAS 05 07 10 13TAVG EE C L C L 280 400 Unit mm 280 300 FILE NO SVM 19040 19 ...
Страница 22: ...RAS 16TKVG EE RAS 16TAVG EE FILE NO SVM 19040 22 ...
Страница 23: ...RAS 18TKVG EE RAS 18TAVG EE FILE NO SVM 19040 23 ...
Страница 135: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...