No.
Part name
Procedures
Remarks
9
Electronic expansion
valve coil
!
Fan Guard
1. Detachment
1) Perform work of item 1 of
2
.
2) Remove the front cabinet, and put it down
so that fan guard side directs downward.
Perform work on a corrugated cardboard,
cloth, etc. to prevent f aw to the product.
3) Remove the hooking claws by pushing
minus screwdriver according to the arrow
mark in the right figure, and remove the fa
guard.
2. Attachment
1) Insert claws of the fan guard in the holes of
the front cabinet.
Push the hooking claws (9 positions) by
hands and fix the claws
All the attaching works have completed.
Check that all the hooking claws are f xed
to the specif ed positions.
Minus screwdriver
Hooking claw
BODY-PMV
COIL-PMV
Rotate 180°C
1.
Detachment
1)
Perform step 1 in
1
, all the steps in
2
and
1 in 5 .
2)
Turn the coil by 180 degrees then remove
by pull it upward.
2.
Attachment
1) Insert the coil at position which
perpendicular with pipe of PMV then turn
the coil by 180 degrees.
Make sure that lead wire of coil
is opposite with pipe of PMV
FILE NO. SVM-19040