Max. : 15m
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
INDOOR UNIT
T1
Temp. measurement
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Allowable
height
difference : 1
2
m
Allo
w
ab
le pipe length
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Pulse Modulating
valve at liquid side
TD
4-way valve
Compressor
KSK89D53UEZ
TS
T2
Outdoor heat
exchanger
Temp. measurement
Propeller fan
OUTDOOR UNIT
Muffler
Muffler
TE
TC
TA
Min. : 2m
Chargeless : 15m
TO
Strainer
Strainer
Refrigerant amount : 0.
46
kg
RAS-
13
T
KVG-
E
E / RAS-13
T
AVG-E
E
NOTE :
• The maximum pipe length of this air conditioner is 20 m. When the pipe length exceeds 15m, the additional
charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 100g)
FILE NO. SVM-19040
- 26 -