FC-22
TROUBLESHOOTING
4 - 72
January 2000 © TOSHIBA TEC
Cause/Defect area
Step
Check items
Measures
Developer unit/
Toner cartridge
Doctor-sleeve gap
Main charger
High-voltage transformer
(main charger/ developer
bias/transfer roller)
Developer material
1
Toner density of developer material proper?
2
Doctor-sleeve gap proper?
3
Foreign matter on charger?
4
Charger wire dirty or deformed?
5
High-voltage transformer output defective?
6
Accumulated copy volume for replacement
attained?
Check and correct auto-toner sensor and toner sup-
ply operation.
Check whether amount of toner is sufficient in toner
cartridge.
Adjust gap.
Remove it.
Clean or replace charger wire.
Adjust output.
Replace developer material.
(16) White spots
F
eeding direaction