ERROR CODE AND TROUBLESHOOTING
8 - 204
[CC21] Saddle stitch 3rd transport roller drive motor (M10) abnormality
MJ-1033
Finisher control PC board (FIN)
•
Connector check
•
Harness check
Saddle control PC board (SDL)
•
Connector check
•
Harness check
Interface PC board (I/F)
Board check
Finisher control PC board (FIN)
Board check
Saddle control PC board (SDL)
Board check
Finisher control PC board (FIN)
Update the firmware version of the finisher control PC board
(FIN).
Saddle control PC board (SDL)
Update the firmware version of the saddle control PC board
(SDL).
Replacement part
Measure
Interface PC board (I/F)
Finisher control PC board (FIN)
Saddle control PC board (SDL)
Error
Timing of detection
Saddle stitch 3rd transport roller
drive motor
Saddle stitch 3rd transport roller
home position sensor
The turning OFF of the saddle stitch 3rd transport roller home
position sensor (S23) is not detected in the specified time when
the saddle stitch 3rd transport roller is nipped or performing
paper transport.
The turning ON of the saddle stitch 3rd transport roller home
position sensor (S23) is not detected in the specified time when
the saddle stitch 3rd transport roller is released.
Probable cause
Checking and measures
Saddle stitch 3rd transport roller
drive motor (M10) abnormality
Check if the electrical continuity of the coil is normal. If
electricity is not conducted, replace the motor.
Saddle stitch 3rd transport roller
home position sensor (S23)
abnormality
Measure the voltage on TP67 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower
when not shielded and within the range of 3.3V
5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connectors. (Finisher control PC board (FIN): CN6, CN16)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the motor, sensor and
connectors, exchange the finisher control PC board (FIN).
Check Item
Measure
Содержание E-STUDIO2008A
Страница 7: ......
Страница 24: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 12 ...
Страница 26: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FEATURES 1 2 ...
Страница 384: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 66 ...
Страница 484: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SETTING ADJUSTMENT 6 100 ...
Страница 988: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 28 ...
Страница 1002: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1008: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1015: ......
Страница 1016: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...