e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 154
[C1A0] LCF end fence motor is abnormal
Classification
Error content
Paper feeding system related service
call
LCF end fence motor is abnormal
Proce
dure
Check item
Result
Measure
Next
Step
1
Is the LCF end fence
motor working? (Perform
the output check in the
test mode: 03-207)
Yes
2
No
1. Check if the connector of the LCF end fence
motor is disconnected.
2. Check if any of the connectors CN1 and
CN5 on the LCF board is disconnected.
3. Check if the connector CN318 on the LGC
board is disconnected.
4. Check if the connector pins are
disconnected and the harnesses are open
circuited.
5. Check if the conductor patterns on the LCF
board and LGC board are short circuited or
open circuited.
6. Replace the LCF board.
7. Replace the LGC board.
2
Are the LCF end fence
home/stop position
sensors working?
(Perform the input check
in the test mode: 03-
[FAX]OFF/[5]/[D], /[5]/[C])
Yes
3
No
1. Check if the connectors of the sensors are
disconnected.
2. Check if either of the connectors CN1 or
CN4 on the LCF board is disconnected.
3. heck if the connector CN318 on the LGC
board is disconnected.
4. Check if the slit reaches the sensors.
5. Check if the connector pins are
disconnected and the harnesses are open
circuited.
6. Check if the conductor patterns on the LCF
board and LGC board are short circuited or
open circuited.
7. Replace the LCF board.
8. Replace the LGC board.
3
LGC board
1. Check if the conductor pattern on the LGC
board is short circuited or open circuited.
2. Replace the LGC board.
Parts to be replaced
Remark
LCF board
LGC board
LCF end fence motor
End fence home/stop position
sensors
Содержание E-STUDIO2008A
Страница 7: ......
Страница 24: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 12 ...
Страница 26: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FEATURES 1 2 ...
Страница 384: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 66 ...
Страница 484: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SETTING ADJUSTMENT 6 100 ...
Страница 988: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 28 ...
Страница 1002: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1008: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1015: ......
Страница 1016: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...