6
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 33
6.6
Image Quality Adjustment (Scanning Function)
6.6.1
Gamma balance adjustment
The density is adjusted by adjusting the gamma balance. The adjustment is performed by selecting its
density area from the following: low density, medium density and high density.
<05 Adjustment Mode>
Notes:
Changing the adjustment setting influences the adjacent density area slightly.
E.g.: When the value of the medium density is larger, the adjacent areas in the low density and
high density range will become slightly darker.
<Procedure>
(1)
Performs FS-05.
(2)
Key in the code corresponding to the desired original mode and press the [START] button.
(3)
Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[START] button.
0: Low density (L), 1: Medium density (M), 2: High density (H)
(4)
Key in the adjustment value. (To correct the value once keyed in, press the [CLEAR] button.)
(5)
Press the [OK] button to store the value in memory.
The equipment goes back to the ready
state.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Turn the power OFF and then back ON. Then perform scanning.
(8)
If the desired image has not been attained, repeat step (2) to (7).
Black
Gray
Scale
Item to be
adjusted
Remarks
Original mode
Text/
Photo
Photo
User
custom
7485-0
7487-0
7480-0
7488-0
Low density
The larger the value is, the density of the item to be
adjusted becomes darker.
Acceptable values:
0 to 255 (Default: 128)
7485-1
7487-1
7480-1
7488-1
Medium density
7485-2
7487-2
7480-2
7488-2
High density
Содержание E-STUDIO2008A
Страница 7: ......
Страница 24: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 12 ...
Страница 26: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FEATURES 1 2 ...
Страница 384: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 66 ...
Страница 484: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved SETTING ADJUSTMENT 6 100 ...
Страница 988: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 28 ...
Страница 1002: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1008: ...e STUDIO2008A 2508A 3008A 3508A 4508A 5008A 2015 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1015: ......
Страница 1016: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...