6
Indoor unit
162
2.
Dimensions
MMD-AP0074BH2UL, AP0094BH2UL, AP0124BH2UL, AP0154BH2UL, AP0184BH2UL, AP0214BH2UL,
AP0244BH2UL, AP0304BH2UL, AP0364BH2UL, AP0424BH2UL, AP0484BH2UL
Air filter slot
5.
8"
(1
47
.5
)
1.9"(49)
Air discharge flange outside
C
Unit external dimension B
5.5"(140)
1.7"(44)
Hanging bolt 4-M0.4"(10)
Ou
ts
id
e
8.
6"
(2
18
.2
)
Hanging bolt pitch A
0.3"
(locally procured)
Drain pipe connecting port
(Liquid side)
Refrigerant pipe
connecting port H
Refrigerant pipe
(Gas side)
connecting port G
5.
2"
(1
31
)
19.6"(498)
Hanging bolt pitch 27.6"(700)
25.1"(638)
Unit external dimension 31.5"(800)
1.6"(41)
2"(50)
2"
(5
0
)
12
.6
"(
32
0
)
5"
(12
7
)
15.1"(384)
2.4"(59)
6.
3"
(1
59
.9
)
Z
1.6"
(4
1
)
1.
7"
(4
2
)
1"(25)
VP25(Polyvinyl chloride tube:
External Dia,1-1/4" Internal Dia,1")
and remote control wiring
1"(26) Hole for control wire
7/8"(22.2) Hole for power supply cable
9.
5"
(2
40
)
Air discharge
side
Air intake
side
1.2"(30)
Air filter slot
2.2"(57)
21
.7
"(
55
0)
o
r
le
s
s
12"(300) or less
Drain-up piping
10
.7
"(
27
1
)
or
les
s
Air intake flange outside
D
Z view
Ou
ts
id
e
9.
6"
(2
43
.2
)
Air intake
side
9.6"(243.2)
12.6"(320)
3.6"(91)
2.
2"
(5
7
)
1.
2"
(3
0
)
Air filter slot
Air intake flange
Air discharge
side
6.3"(159)
<Under air intake type>
For air intake from under air intake, be sure to attach a separately-sold fan guard.
Space required for installation and servicing
Reserve space required for maintenance the indoor unit and service work.
4"
(1
00
)
5.9"(150) or more
Space required for attaching or
detaching the filter F
Check port B
17.7"X17.7"
(450X450)
Space required for attaching or
detaching the filter F
4"
(1
00
)
5.9"(150) or more
Air discharge
Ceiling opening size E
Unit width B
Air discharge
5.9"(150)
31.5"(800)
Ceiling opening size
38.6"(980)
1.2"(30)
Air intake
Ceiling
Electrical
control box
Electrical control box
Air filter
(locally procured)
Ceiling
Drain pan / Drain
pump check cover
Check port A
17.7"X17.7"
(450X450)
Ceiling opening size
Air filter
(locally procured)
Electrical control box
Notes)
* Set check port A for maintaining the electrical control box, filter, drain pump, drain pipe, and refrigerant pipe.
* Replace the filter through check port A or B.
(If you pull out the filter in the opposite direction of the electrical control box, check port B is required.)
Reserve space F required for attaching or detaching the filter.
Otherwise, the filter cannot be replaced.
* When pulling the refrigerant pipe, drain pipe, etc, avoid the filter port. Otherwise,the filter cannot be replaced.
* The indoor unit is not equipped with an air filter. Procure and install with locally.
* Set a ceiling opening port for maintaining the fan, fan motor, etc. Otherwise, they cannot be maintained.
*1 In the case of under air intake type.
: 17.7"(450)(Min.)
15
.5
"(
40
0
)
(Min
.)
*1
Unit: in (mm)
Model
MMD-
A
B
C
D
E
F
G
H
AP0074BH2UL, AP0094BH2UL,
AP0124BH2UL
24.3"
(616)
21.7"
(550)
13.9"
(351.6)
18.6"
(471.6)
23.6"
(550)
23.6"
(550)
Ø3/8"
(9.5)
Ø1/4"
(6.4)
AP0154BH2UL, AP0184BH2UL
42"
(1066)
39.4"
(1000)
31.6"
(801.6)
36.3"
(921.6)
41.3"
(1050)
23.6"
(550)
Ø1/2"
(12.7)
Ø1/4"
(6.4)
AP0214BH2UL, AP0244BH2UL,
AP0304BH2UL, AP0364BH2UL,
AP0424BH2UL, AP0484BH2UL
55.7"
(1416)
53.2"
(1350)
45.4"
(1151.6)
50.1"
(1271.6)
55.1"
(1400)
40.5"
(1030)
Ø5/8"
(15.9)
Ø3/8"
(9.5)
Содержание Carrier MMC-AP0181H2UL
Страница 60: ...5 Outdoor unit 59 5 2 2 Heat pump 5 2 2 1 Single unit Model MMY MAP0724HT9UL MAP0724HT6UL 72 9 ...
Страница 61: ...5 Outdoor unit 60 Model MMY MAP0964HT9UL MAP0964HT6UL MMY MAP1144HT9UL MAP1144HT6UL 72 9 ...
Страница 75: ...5 Outdoor unit 74 5 6 Wiring diagram 5 6 1 Heat recovery Model MMY MAP0724FT9UL 208 230 V 60 Hz ...
Страница 76: ...5 Outdoor unit 75 Model MMY MAP0724FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Страница 77: ...5 Outdoor unit 76 Model MMY MAP0964FT9UL MAP1204FT9UL 208 230 V 60 Hz ...
Страница 78: ...5 Outdoor unit 77 Model MMY MAP0964FT6UL MAP1204FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Страница 79: ...5 Outdoor unit 78 5 6 2 Heat pump Model MMY MAP0724HT9UL ...
Страница 80: ...5 Outdoor unit 79 Model MMY MAP0724HT6UL ...
Страница 81: ...5 Outdoor unit 80 Model MMY MAP0964HT9UL MAP1144HT9UL ...
Страница 82: ...5 Outdoor unit 81 Model MMY MAP0964HT6UL MAP1144HT6UL ...
Страница 212: ...MEMO ...
Страница 213: ...Engineering Data Book For North America August 2015 First Edition ...