2.PRINTER SETUP
ENGLISH VERSION EO1-33094
2.10 Threshold Setting
E2-69
2.10 Threshold Setting
(Cont.)
Display
example
Explanation
1
Result: OK (Mid.)
Threshold is at the midpoint between the
peak and the baseline.
2
Result: OK (High)
Threshold is near the peak voltage, so
detection of a gap/black mark may fail if
the voltage difference is very small.
Adjusting the threshold to the midpoint
between the peak and the baseline
enables more accurate detection. Follow
next (5) to (10)
3
Result: OK (Low)
Threshold is near the baseline voltage,
so detection of a gap/black mark may fail
if the voltage difference is very small.
Adjusting the threshold to the midpoint
between the peak and the baseline
enables more accurate detection. Follow
next (5) to (10)
4
Failed (1)
The media sensor cannot detect a
gap/black mark. Sensor adjustment is
required. (
⇒
Section 2.11
)
5
Failed (1)
The media sensor cannot detect a
gap/black mark. (Threshold
≤
Baseline)
Sensor adjustment is required.
(
⇒
Section 2.11
)
6
Failed (2)
Detection by the media sensor is
disabled. Sensor adjustment is required.
(
⇒
Section 2.11
)
(5) To return to the sensor selection screen, press the [FEED].
To terminate the threshold setting, press the [ENTER].
To see the details, press the [RIGHT].
(e.g: Succeeded)
(e.g.: Failed)
Sensor type
Peak voltage
Threshold voltage
Baseline voltage
Key operation guide
NOTE:
To make a threshold value
set in this section effective,
select the Transmissive
Sensor (when using pre-
printed media) or Reflective
Sensor (when using manual
threshold value) in Issue
Command or the printer
driver.