4-9
65/5560 PERIODIC
MAY.1997 © TOSHIBA CORP.
Explanation of items in the "REMARKS" column of the Periodic Inspection Check List
*1 Main blade
If poor cleaning occurs due to the adhesion of paper dust, etc. before the specified number of copies
for replacement have been reached, the edge of the blade has been damaged.
Replace the blade if necessary,while change fur brush siwuitaneously.
*2 Recovery blade
If the edge of the blade is damaged, replace the blade regardiess of the number of copies made so
far.
*3 Separation claw
If any abnormal condition (e.g. coating wear) is observed on the tip of separation claw and ifthe mark
of the separation claw is observed on the copy image, replace the claw regardless of the number of
copies made so far.
Clean the tip of the claw by lightly wiping with a dry cloth. In addition, be sure to apply patting powder
(lubricant) to the separation claw after cleaning the claw and when replacing the claw or drum.
*4 Drum
Refer to section 5.2 "Inspection and Cleaning of the OPC Drum".
*5 Air filter
If the air filter is dirty, replace it.
*6 Charger wire and case
Clearn the charger case and the charger wire with a cloth which should be soaked in water and then
squeezed tightly.
*7 Developer material
After replacing the developer material, be sure to adjust the auto-toner sensor.
*8 Upper and lower heat rollers
Refer to section 5.4 "Checking and Cleaning of the Upper and Lower Heat Rollers".
ADF front section view
84
83
88
82
89 90
86
92
85
87
91
Содержание 65/5560
Страница 61: ...4 5 65 5560 PERIODIC MAY 1997 TOSHIBA CORP Front section view upper unit ...
Страница 62: ...4 6 MAY 1997 TOSHIBA CORP 65 5560 PERIODIC Front section view lower unit 74 75 74 76 75 74 76 75 76 77 77 97 W ...
Страница 63: ...4 7 65 5560 PERIODIC MAY 1997 TOSHIBA CORP Rear side view upper unit ...
Страница 64: ...4 8 MAY 1997 TOSHIBA CORP 65 5560 PERIODIC Rear side view lower unit 80 W 80 W 3 ...