Torrey EchoTherm HP60 SERIES Скачать руководство пользователя страница 3

Congratulations on your purchase of an EchoTherm™ Programmable Hot Plate or Hot Plate/ 
Stirrer.  Please read the instructions carefully to insure that you receive the maximum benefit 
from it.  Also, be sure to fill out and return the enclosed warranty registration card. 
 
 

II. WARRANTY

 

 

Torrey Pines Scientific warrants this product to be free from defects in material and 
workmanship for a period of one year from the date of purchase.  If repair or adjustment is 
necessary and has not been the result of abuse or misuse within the one year period, please 
return---freight prepaid--and correction of the defect will be made without charge. 
 
Out-of-warranty products will be repaired on a charge basis. 
 
 

III. RETURN OF ITEMS 

 

Authorization must be obtained from our Customer Service Department before returning 
items for any reason

.  When applying for authorization, please include data regarding the 

reason the items are to be returned.  For your protection, items must be 

carefully packed

 to 

prevent damage in shipment and 

insured

 against possible damage or loss.  Torrey Pines 

Scientific will not be responsible for damage resulting from careless or insufficient packing.  A 
15% restocking charge will be made on all unauthorized returns. 
 

NOTE: 

Torrey Pines Scientific reserves the right to make improvements in design, construction, 

and appearance without notice. 
 
 

IV. LABELS  

 

There are various labels on the body of this unit.  Listed below are the labels and their meanings. 
 

This symbol means: 

Attention. The instruction manual is to be consulted for  

  further 

information. 

 

Attention: Lire ce manuel pour des informations    

  complémentaries. 

 

 

 
This symbol means: 

Warning, Hot Surface.  Attention, surface chaude.

 

 

 
This symbol means: 

Ground or earth connection.  Connexion á la terre.

 

 

V. CAUTIONS 

 

HEATER PLATE SURFACE 

Содержание EchoTherm HP60 SERIES

Страница 1: ...SERIES DOCUMENT NUMBER HP60 HS60 1 Revised 17 January 2011 TORREY PINES SCIENTIFIC INC 2713 Loker Ave West Carlsbad CA 92010 TELEPHONE 760 930 9400 Toll Free 866 573 9104 FAX 760 930 9480 E MAIL info...

Страница 2: ...FRONT AND REAR PANEL CONTROLS 6 7 VIII SET UP INSTRUCTIONS 8 IX DISPLAY AND KEYBOARD DESCRIPTION 9 10 11 X SIMPLE OPERATIONS 11 12 13 XI PROGRAM OPERATIONS 13 14 15 XII TEMPERATURE CALIBRATION 15 16 X...

Страница 3: ...returning items for any reason When applying for authorization please include data regarding the reason the items are to be returned For your protection items must be carefully packed to prevent dama...

Страница 4: ...umber HS30 600 For other probes available in other lengths and materials call the factory or consult your price list All probes come with 3 foot 91 44 cm interconnect cable and are 3 16th 47 6 mm in d...

Страница 5: ...he unit has an AUTO OFF function When the AUTO OFF function is activated the heater and stirrer will turn off at the end of any count down timer setting ALARMS In addition to the audible alarm associa...

Страница 6: ...ral icons which function to display all parameters when the unit is running and during setting When the unit is turned on the display will come on and show the actual plate surface temperature If a pr...

Страница 7: ...The fuse types used appear on the label on the rear of the unit CAUTION If the fuses blow repeatedly contact your dealer or the manufacturer ATTENTION Si les fusibles sautent de mani re r p titive co...

Страница 8: ...container 5 Turn on the unit by the key on the front panel The unit will beep once and the display will light up At this point the user can set or view any of the parameters of the unit 6 Set either t...

Страница 9: ...sition being monitored All stirrer positions can be checked this way Ramp When the RAMP key is depressed the C symbol to the right of the top line of the display with convert to C hr The number value...

Страница 10: ...alue will move around showing each stirrer position Stop on the one to be set and use the UP DOWN RIGHT LEFT arrows to set the stirrer speed in RPM Timer Button The TIMER is for setting the value of t...

Страница 11: ...change to F depress and hold the HEATER OFF button until the display changes To change back to C repeat the process Setting Solution Temperature When setting a solution temperature plug the probe int...

Страница 12: ...that the unit will heat fastest when not using a ramp rate setting even 450 C Hour The ramp rate should only be used to slow the heating rate It is valuable to note that the ramp can be set to go up t...

Страница 13: ...ll be sitting with the same information on the display as when the unit was first turned on To stop a program while it is running touch CANCEL Some rules for programming To erase all programs in memor...

Страница 14: ...display will show 2 for program step two Now enter the values for ramp temperature stirrer and timer being certain to hit ENTER after each Step 2 is now complete 6 Repeat the steps above until the pr...

Страница 15: ...25 C dummy probe in the probe jack at the rear of the unit Depress and hold the HEATER button for 3 seconds until the display reads CAL Then press ENTER Then use the UP DOWN RIGHT LEFT arrows to make...

Страница 16: ...onds until the display reads CAL Then press the ENTER button Use the UP DOWN RIGHT LEFT arrows as needed to make the plate temperature display read what is measured on your meter Then press the ENTER...

Страница 17: ...qu elle est chaude pour viter toute br lure accidentelle Maintenance There is no ongoing maintenance program needed with this unit other than the normal care and cleaning as instructed above and a sim...

Страница 18: ...O Mains Off XV RS232 SERIAL INTERFACE SPECIFICATION See the following pages 18...

Отзывы: