Fuel Stop (ETR) Solenoid
The Reelmaster
®
5100-D has an energize-to-run (ETR)
fuel stop solenoid. The solenoid will stop injector pump
fuel delivery with any electrical failure in the RUN circuit.
1. Disconnect the wire connector and remove the fuel
stop solenoid from the engine (Fig. 21).
2. Connect a 12 volt battery so the positive (+) battery
terminal is connected to terminals A (hold) and B (pull)
(Fig. 22). Connect the negative (–) battery terminal to
solenoid terminal C (common). The plunger should
retract to the dimension shown.
IMPORTANT: Do not connect Voltage to terminal B
(pull) for more than 30 seconds or damage to the
solenoid coil could result.
3. With the battery connected the same as step 2,
disconnect the battery from solenoid terminal B (pull).
The plunger should remain pulled in.
4. Disconnect the battery from terminal A (hold). The
plunger should return to the extended position.
5. Check the solenoid internal spring tension. The spring
must have 9.2 lbs (4.2 kg) minimum force with the
plunger in the extended position.
Replace the fuel stop solenoid if it fails any of the above
tests. (See Replacing and/or Adjusting Stop Solenoid in
the External Engine Component Repair section of
Chapter 3 - Engine.)
To Test While Connected to Wire Harness
1. Remove the governor tie rod cover so you can
observe the solenoid plunger.
2. Hold the manual fuel stop lever back to prevent fuel
delivery. Turn the key switch to the START position and
quickly return it to the ON position. The solenoid plunger
should be retracted.
3. Turn the key switch to the OFF position. The solenoid
plunger should extend.
NOTE: You can also test operation without removing the
governor tie rod cover. Listen for an audible “click” as
the solenoid extends and retracts while doing steps 2
and 3 of the above procedure. This will not show if the
solenoid is adjusted correctly or if it is fully extending
and retracting. (See Replacing and/or Adjusting the
Stop Solenoid in the External Engine Component Re
pair section of Chapter 3 - Engine.)
1
2
3
Figure 21
1. Fuel stop (ETR) solenoid
2. Wire connector
3. Governor tie rod cover
Energized
0.12 in.
(3 mm)
A
B
C
0.65 in.
(16.5 mm)
De-energized
+
—
12 V.D.C
Figure 22
A. Hold
B. Pull
C. Common (ground)
Testing
Page 5 - 24
Reelmaster
®
5100-D
Содержание Reelmaster 5100-D
Страница 2: ...This page is blank ...
Страница 4: ...This page is blank ...
Страница 8: ...Safety Instructions Page 1 4 Reelmaster 5100 D ...
Страница 12: ...Maintenance Interval Chart Maintenance Interval Chart Page 2 4 Rev A Reelmaster 5100 D ...
Страница 32: ...Troubleshooting Page 3 16 Reelmaster 223 D 5100 D ...
Страница 33: ...Reelmaster 223 D 5100 D Page 3 17 Troubleshooting ...
Страница 86: ...Specifications Page 4 2 2 Reelmaster 5100 D ...
Страница 90: ...Hydraulic Schematic Rev A Hydraulic Schematic Page 4 6 Reelmaster 5100 D ...
Страница 154: ...Logic Chart Page 5 2 Reelmaster 5100 D ...
Страница 155: ...Wiring Schematic S N Below 51001 Rev B Reelmaster 5100 D Page 5 3 Wiring Schematic ...
Страница 206: ...Repairs Page 5 48 Rev A Reelmaster 5100 D ...
Страница 230: ...Repairs Page 6 24 Reelmaster 5100 D ...
Страница 304: ...Repairs Page 8 22 Reelmaster 223 D 5100 D 5300 D ...
Страница 317: ...This page is blank ...
Страница 318: ...Commercial Products The Toro Company ...