Glow Relay
To test the glow relay (Fig. 17), disconnect the relay wire
connector and install a continuity tester between the
relay terminals (terminals 30 and 87) (Fig. 19). The relay
should make and break continuity at terminals 30 and
87 as 12 V.D.C. is connected and disconnected to
terminal 85 with terminal 86 connected to ground.
85
86
30
87
RE
D/
W
HI
T
E
OR
A
N
GE
RE
D
Figure 19
Battery
1. Use a volt-ohm meter to measure the voltage be
tween the battery terminals.
2. If the voltage is less than 12.3 Volts D.C. , the battery
should be charged.
NOTE: Regulated voltage will increase to 13.5 Volts
when the engine is running.
Figure 20
Reelmaster
®
5100-D
Page 5 - 23
Testing
Содержание Reelmaster 5100-D
Страница 2: ...This page is blank ...
Страница 4: ...This page is blank ...
Страница 8: ...Safety Instructions Page 1 4 Reelmaster 5100 D ...
Страница 12: ...Maintenance Interval Chart Maintenance Interval Chart Page 2 4 Rev A Reelmaster 5100 D ...
Страница 32: ...Troubleshooting Page 3 16 Reelmaster 223 D 5100 D ...
Страница 33: ...Reelmaster 223 D 5100 D Page 3 17 Troubleshooting ...
Страница 86: ...Specifications Page 4 2 2 Reelmaster 5100 D ...
Страница 90: ...Hydraulic Schematic Rev A Hydraulic Schematic Page 4 6 Reelmaster 5100 D ...
Страница 154: ...Logic Chart Page 5 2 Reelmaster 5100 D ...
Страница 155: ...Wiring Schematic S N Below 51001 Rev B Reelmaster 5100 D Page 5 3 Wiring Schematic ...
Страница 206: ...Repairs Page 5 48 Rev A Reelmaster 5100 D ...
Страница 230: ...Repairs Page 6 24 Reelmaster 5100 D ...
Страница 304: ...Repairs Page 8 22 Reelmaster 223 D 5100 D 5300 D ...
Страница 317: ...This page is blank ...
Страница 318: ...Commercial Products The Toro Company ...