g032394
Figure 17
1.
Frame
3.
Hose bracket
2.
Bolts (5/16 x 5/8 inch)
2.
Torque the bolts to 1978 to 2542 N∙cm (175 to
225 in-lb).
3.
Position an R-clamp over each hose (
).
g032395
Figure 18
1.
Supply hose
4.
Return hose
2.
R-clamp
5.
Flange nut (1/4 inch)
3.
Carriage bolt (1/4 x 3/4
inch)
4.
Use the 2 carriage bolts (1/4 x 3/4 inch) and
flange nuts to install the R-clamp and hose
assembly to the bracket mount (
).
5.
Torque the bolt to 1017 to 1243 N∙cm (90 to 110
in-lb).
5
Routing the Heater Hoses
Parts needed for this procedure:
1
Hose clamp (1/2 to 1-1/4 inches)
1
Straight fitting (3/8 npt x 0.625 barb)
1
Temperature sensor (Yanmar engine only)
1
Adapter (Yanmar engine only)
Routing the Supply Hose
Kubota Engine Only
1.
Route the supply hose as shown in
g032423
Figure 19
1.
Supply hose
2.
Return hose
2.
Locate, disconnect, and remove the temperature
sensor (
).
14