Reset Regeneration
g214711
Figure 38
Assist/reset-regeneration icon
•
The assist/reset-regeneration icon displays in the
InfoCenter (
).
•
The computer takes control of the intake throttle
and changes the fuel injection operation to
increase the temperature of the engine exhaust.
Important:
The assist/reset-regeneration
icon indicates that the exhaust temperature
discharged from of your machine may be
hotter than during regular operation.
•
While operating the machine, run the engine at
full engine speed when possible to promote DPF
regeneration.
•
The
icon displays in the InfoCenter while
the reset regeneration is processing.
•
Whenever possible, do not shut off the engine or
reduce engine speed while the reset regeneration
is processing.
Important:
Allow the machine to complete the
reset regeneration process before shutting off
the engine.
Note:
The reset regeneration is finished
processing when the
icon disappears from
the InfoCenter.
Parked Regeneration
g214713
Figure 39
Parked-regeneration request icon
•
The parked-regeneration requested icon displays
in the InfoCenter (
).
•
If a parked regeneration is needed, the InfoCenter
displays engine warning SPN 3719, FMI 16
(
) and the engine computer derates
engine power to 85%.
g213866
Figure 40
Important:
If you do not complete a parked
regeneration within 2 hours, the engine
computer derates engine power to 50%.
•
A parked regeneration requires 30 to 60 minutes
to complete.
•
If you are authorized by your company, you need
the PIN code to perform the parked-regeneration
process.
Preparing to Perform a Parked or Recovery
Regeneration
1.
Ensure that the machine has at least 1/4 tank
of fuel.
2.
Move the machine outside to an area away from
combustible materials.
3.
Park the machine on a level surface.
4.
Ensure that the traction control or motion-control
levers are in the N
EUTRAL
position.
5.
If applicable, lower the cutting units and shut
them off.
33