8.
Route the long hose under the radiator frame, over the
frame cross member, and along the frame rail to the
valve (
).
Note:
The long hose will follow another hose from
the transmission bay to the valve assembly.
Figure 20
1.
Cable tie
3.
Valve
2.
Long hose
9.
Secure the long hose with 4 cable ties (
).
10.
Secure the hose fitting to the straight fitting (
).
5
Installing the Relays and
Switches
Model 30810
Parts needed for this procedure:
1
Relay bracket
6
Relay
6
Bolt (1/4 x 1/2 inch)
7
Nut (1/4 inch)
1
Bolt (1/4 x 3/4 inch)
1
Decal (from Auxiliary Power Unit Kit)
2
Switch
Procedure
1.
On the right side of the machine, mount 6 relays onto
the relay bracket using 6 bolts (1/4 x 1/2 inch) and 6
nuts (1/4 inch) as shown in
Figure 21
1.
Bolt (1/4 x 1/2 inch)
5.
Support-tube nut
2.
Relay
6.
Relay bracket
3.
Nut (1/4 inch)
7.
Bolt (1/4 x 3/4 inch)
4.
Support-tube bolt
2.
Remove the bolt and nut from the support tube.
3.
Using a bolt (1/4 x 3/4 inch), nut (1/4 inch), and the
bolt and nut that you just removed, mount the relay
bracket to the machine (
9