6
Installing the Relays and
Switches
Model 30812
Parts needed for this procedure:
1
Relay bracket
6
Relay
6
Bolt (1/4 x 1/2 inch)
7
Nut (1/4 inch)
1
Bolt (3/8 x 2 inches)
1
Washer (0.406 inch)
1
Nut (3/8 inch)
6
Bolt (1/4 x 1/2 inch)
6
Locknut (1/4 inch)
1
Decal (from Auxiliary Power Unit Kit)
2
Switch
Procedure
1.
Loosely mount the relay bracket to the frame using a
bolt (3/8 x 2 inches), washer (0.406 inch), and nut (3/8
inch), as shown in
Figure 25
1.
Bolt, nut, and washer
3.
Mark here.
2.
Relay bracket
2.
Mark the location indicated in
.
3.
Remove the bracket, and drill a hole (0.281 inch)
through both walls of the frame in the location that
you marked.
4.
Install the bracket with the hardware you used to
loosely install the bracket and secure the bracket to the
new hole with a bolt (1/4 x 2-1/2 inches) and nut (1/4
inch).
5.
Install the 6 relays to the bracket using 6 bolts (1/4 x
1/2 inch) and 6 locknuts (1/4 inch).
Figure 26
1.
Bolt (1/4 x 1/2 inch)
3.
Locknut (1/4 inch)
2.
Relay
6.
Unlatch the control-panel cover and move it aside
(
).
Figure 27
1.
Control panel
2.
Latch
11