5.8
EMERGENCY PROCEDURES
If the window must be opened manually due to lack of
electricity or because the mechanism locks, follow the
instructions below:
Top hung opening:
Fig. 41-
Insert a screw driver in the
right side opening (Ref. 1) as shown in figure,
disconnect the chain end from the ARS coupling and
extract the actuator;
Bottom hung window opening:
Fig. 42 -
Put a cut
screwdriver between the bottom hung window
bracket and the chain terminal and lift up until the
chain terminal is disengaged.
Should it be impossible to perform the above mentioned
procedures, disconnect the clamps from the window
frame connection brackets.
Before performing any type of intervention on the
actuator and on the window the following must be done:
disconnect the branching device from the power supply
network;
to avoid unexpected start-ups, lock the branching
device's main switch that is installed on the power
supply line; if the main switch cannot be locked, a “do
not operate” warning sign must be affixed.
6.1
USE OF THE ACTUATOR
USE AND OPERATION
6
APPENDIX
7
7.1
MAINTENANCE
If the actuator shows any malfunctions, contact the
manufacturer.
Any work on the actuator or any of its parts (power cord,
etc.) must be done exclusively by personnel qualified by
the manufacturer. Topp is not liable for any work done by
unauthorized persons.
Extraordinary and routine maintenance operations
involving the total or partial dismounting of the actuator
may only be performed after disconnecting it from the
power supply.
The design of the actuator provides for use of parts that
do not require regular routine or special maintenance of
great significance.
The recommended maintenance activities should in any
case involve the periodical execution (every 6 mounths)
of at least the following operations: the elements in the
actuator unit, the replacement of components that show
signs of superficial damage such as injuries, cracks,
discoloration, etc., the seal of the fastening systems
(brackets and screws), possible deformation of the
window fittings and consequent seal of the gaskets, as
21
EN
INSTALLATION AND USE INSTRUCTIONS
C240
Use of the actuator must be assigned exclusively to
users who comply with the instructions in this
manual and/or in the manual of the actuator control
unit (power and control unit).
Use of the actuator serves to open and close the window
automatically depending on the control device installed
(
see par. 5.5
).
Before using, make sure there are no people, animals or
objects near the window that could accidentally be
injured (
see par. 4.4
).
During use of the actuator, always stay in a safe position
that ensures visual control of the window's movement.
Do not operate dome windows in the presence of a load
of snow in excess of the quantity declared acceptable by
the window manufacturer.
Always check the efficient performance and function of
the actuator and window on which it is installed, as well as
the electrical system, performing any routine or special
maintenance necessary to ensure safe working
conditions.
All the above actions must be carried out exclusively by
qualified technical personnel in possession of the
professional requisites foreseen by the legislation in
force in the country of installation.
In order for the automation unit to operate correctly, we
recommend carrying out periodical maintenance on it, as
indicated in par. 7.1 of this manual.
TOPP informs the user that, in accordance with art. 8 of
Ministerial Decree no. 38 of 22.1.2008, the owner of the
system is responsible for adopting all necessary
measures to maintain the safety features set out in
applicable legislation, observing the instructions for
maintenance and use provided by the manufacturer of
the device and by the company that carried out the
installation.
central OFF position;
Optional - Power and control unit: TOPP microprocessor
control units model TF that control a single actuator or
several actuators simultaneously with one or more
manual buttons, an infrared remote control or radio
control at 433 Mhz. Rain, wind and light sensors can be
connected to these control units.
Any control units used must furnish power to the C240 for
a maximum time of 120 seconds.
7.2
DEMOLITION
Demolition of the actuator must be made in respect of the
legislation in force on the subject of environmental
safeguards. Proceed with differentiation of the actuator
parts according to the different type of material (plastic,
aluminum, etc.).
7.3
SPARE PARTS AND ACCESSORIES
AVAILABLE ON REQUEST
Always use original spare parts and accessories to
ensure the safety and efficient operation of the actuator .
Original spare parts and accessories must be ordered
e x c l u s i v e l y f r o m t h e d e a l e r o r m a n u f a c t u r e r,
communicating the type, model, serial number and year
of construction of the actuator.
well as the state of the wiring and connections.
This maintenance activity may be carried out either by
TOPP, in accordance with a specific agreement made
with the user, or by the installation technician or by other
competent and qualified technical personnel in
possession of all legal requirements.
Содержание C240
Страница 2: ......
Страница 12: ...12 ISTRUZIONI PER L INSTALLAZIONE E L USO IT C240 ...
Страница 22: ...22 INSTALLATION AND USE INSTRUCTIONS EN C240 ...
Страница 33: ...33 C240 ISTRUCCIONES PARA LA INSTALLACION Y EL EMPLEO SP ...
Страница 43: ...43 C240 DE INSTALLATIONS UND WARTUNGSANLEITUNGEN ...
Страница 54: ...INSTRUCTIONS POUR L INSTALLATION ET L EMPLOI 54 FR C240 ...
Страница 55: ...55 NOTE NOTES NOTES NOTAS C240 ...
Страница 66: ...66 C240 Fig 20 Y I 2 I 2 A B I 2 5 mm Fig 21 Fig 22 A B A B Fig 23 1 FIGURE FIGURA ABBILDUNGEN ...
Страница 69: ...69 C240 Fig 30 Z I 2 I 2 B A I 2 5 mm Fig 31 Fig 33 Fig 34 A B Fig 32 A B A B A B FIGURE FIGURA ABBILDUNGEN ...
Страница 75: ......