62
of lock. The
Static Mode
checkbox is associated with the receiver pa-
rameter
/par/raw/clp/static
.
The receiver will take the above-described parameter into consideration only if the
receiver antenna is stationary and
Enable Co-Op tracking
is selected.
•
The
Bandwidth of individual PLL
and
Bandwidth of common PLL
edit
boxes mean exactly what their names imply:
♦
Bandwidth of individual PLL
is associated with the receiver parameter
/par/raw/clp/indband
;
♦
Bandwidth of common PLL
is associated with the receiver parameter
/par/raw/clp/comband
.
Select the
Enable L2 common loop
checkbox to avoid the loss of L2 phase tracking in dy-
namic applications due to antenna rotation around its axis. The checkbox corresponds to the re-
ceiver parameter
/par/raw/clp2/loop
.
External Frequency
The settings on this subtab (Figure 42), allow the operator to configure the use of reference fre-
quency (it may be either high-stability external frequency or the receiver’s internal crystal oscilla-
tor).
Figure 42. “External Frequency” subtab
With the controls in the
Source
group, the user specifies the reference frequency input that the
receiver will use:
•
Internal
– means the receiver uses the internal oscillator.
•
External
– means the receiver uses an external frequency.
These radio buttons are associated with the receiver parameter
/par/frq/input
.