90
3-7-3
REFILLING OF NITROGEN GAS
1.
Fit a pressure regulator (2) and hose (3)
onto the nitrogen gas cylinder (1)
2.
Fit a filling adapter (4) to the end of the
hose and insert the adapter into the gas
valve
3.
Open the regulator valve (B) of the
nitrogen gas cylinder
4.
Turn the handle (A) of the pressure
regulator (2) while reading the pressure
gauge of the regulator. Fill with nitrogen
gas up to the pressure shown in the table
5.
Stop turning the handle (A) after the gas
pressure reaches the correct value shown
in the table and keep it there for about 10
seconds.
Make sure the pressure regulator handle (A) is loosened.
When refilling the nitrogen gas, make sure the hydraulic breaker is cooled off.
CAUTION
CAUTION
3
1
A
B
A
WARNING
Do not use any other gas except nitrogen gas.
In other gases are used, it may explode and is dangerous.
2
2
4
WARNING
It does not perform the replenishment of nitrogen gas immediately after operation.
Since each unit is hot, it is possible to burn. Please perform the work from the cold is always
oil and various parts.
Содержание TNB-08M