49
大きい枕木
2-15.
STORAGE OF THE BREAKER
When the hydraulic breaker is not being used for a long period of time,
proceed as follows:
2-15-1. STORAGE FOR ONE MONTH
Apply grease to the retainer-pin holes (1).
1.
Place the breaker on 2 pieces of wood (A).
NOTE: Lay the breaker down so that the
cylinder side is higher than the chisel holder
side.
2.
Remove the hex plug (2) from the chisel
holder.
Spray anti-rust spray (C) onto the piston area
and replace the hex plug (2) in the chisel
holder.
・P.S. : In regard of the models of TNB-7J upward with
side mount silenced brackets remove the plug(3)first
and follow the work 2 after.
3.
Place a sheet (D) over the breaker for
storage.
In this case the chisel side must be lower to
avoid the rain water penetration in the chisel
holder.
1
A
A
2
C
D
3
CAUTION
When washing the breaker by high pressure
water, make sure that the water does not into
chisel holder and air cap. The penetrated water
can be accumulated into inside of the breaker,
and then it causes rusts inside of the breaker.
×