87
3-7. INSPECTION OF NITROGEN GAS PRESSURE AND RECHARGE
⚫
Inspect the nitrogen gas pressure every 100 hours or 1 month
.
⚫
Nitrogen gas is contained inside the cylinder cover of the hydraulic breaker. The impact force will
decrease if the gas pressure reduces.
If the gas pressure low, fill the cushion chamber with nitrogen gas according to the following
procedures
Do not use any other gas except nitrogen gas.
If other gases are used, it may explode and is dangerous.
When filling nitrogen gas, the chisel may suddenly come out. Therefore, keep away from the
chisel when refilling with nitrogen gas.
WARNING
WARNING
CAUTION
Do not charge nitrogen gas pressure more than specified. It will shorten the life of the
seal and cause malfunction.
Содержание TNB-08M