ENGINE OPERATION
41
7
ENOM01807-0
Side mount RC type
1. Be sure to install the stop switch lock
to the stop switch, and attach the
stop switch lanyard securely to the
operator or to the operator's PFD
(Personal Flotation Device.)
1.
Stop switch lock
2. Insert the main switch key.
3. Set the control lever in the Neutral
position. Do not raise the free throt-
tle lever when starting the engine.
1.
Neutral (N)
2.
Control lever
3.
Fully opened (Forward)
4.
Fully opened (Reverse)
5.
Free throttle lever
6.
Main switch key
7.
Stop switch
4. Turn the main switch key to ON posi-
tion and confirm three warning lamps
light up with buzzer sound and then
go off.
1.
Warning lamp
5. Turn the main switch key to the START
position and release it to start the
engine. The engine will crank continu-
ously until the engine starts.
ENON00942-0
Note
z
It takes maximum 4 seconds of the
continuous crank before the engine
starts.
z
If fail to start the engine, crank again
after 10 seconds or more.
1.
ON
2.
START
3.
OFF
ENON00035-A
Note
The free throttle lever can not be raised
when the control lever shift is in Forward
or Reverse.
1
ENOF00869-1
N
R
F
1
2
3
4
5
6
7
ENOF00870-1
1
ENOF00851-A
1
2
3
ENOF00871-1