Chapter 9: CONNECTIONS
7. cABlE DISTANcE BETWEEN cOmPONENTS
9-42
6
3
RJ45 male connector
Use Cat.5 cable's inner wires.
The rJ45 male connector needs to be arranged for use as a terminator referring to the procedure below.
All the parts used here should be prepared locally.
As for a 100 Ω resistor among the parts, it is available as a service part as follows.
• Mounting a terminator on the RM-200X
LINK
DC POWER IN
24V
MIC
SP
EXTERNAL
MIC IN
RM-200X Rear
To the next Remote Microphone
or VX-200XR
Terminator
Step 1.
fasten cat.5 cable's inner wires in Pins 3 and 6 of the rJ45 male connector using a crimp tool.
Resistor 100 Ω
Protective modular cover
Step 2.
Solder a 100 Ω resistor to the ends of both cables.
Step 3.
mount a protective modular cover onto the connector.
Step 4.
Plug the assembled terminator into the rm-200X's lINK connector not in use.
Note
mount the terminator on the last rm-200X
connected only to the modified VX-200Xr
for doubly terminated bus topology.
Parts
Quantity
Description
100 Ω resistor
1
1/4 W or 1/5 W
Equivalent to TOA Part Code 112-31-041-10 (R25 100 Ω 5%)
or TOA Part Code 112-71-025-70 (R20 100 Ω 5%)
Содержание VP-2241
Страница 12: ...Chapter 1 Note...
Страница 17: ...Chapter 2 ProduCt desCriPtioNs...
Страница 41: ...3 1 Chapter 3 system oPeratioN outliNe...
Страница 56: ...Chapter 4 FuNCtioNs...
Страница 73: ...Chapter 5 oPeratioN...
Страница 112: ...Chapter 6 FloWCHart From system setuP to oPeratioN...
Страница 116: ...Chapter 7 PC soFtWare oFFliNe settiNGs...
Страница 179: ...Chapter 8 iNstallatioN aNd settiNG ProCedures HardWare...
Страница 223: ...Chapter 9 CoNNeCtioNs...
Страница 266: ...Chapter 10 PC oNliNe CHeCKs aNd adJustmeNts...
Страница 282: ...Chapter 11 otHer PC soFtWare FuNCtioNs...
Страница 292: ...Chapter 12 aPPeNdiX...
Страница 298: ...Chapter 13 sPeCiFiCatioNs...
Страница 328: ...url http www toa jp 201409...