17
Detach
Attach
Approx. 100 mm
Sealing tape
Pipe
8.2. Open Wiring from the Camera's Side
1. Detach the pipe receptacle cover on the camera side, then attach it to the case's top surface.
2. Wrap two or more turns of sealing tape around the pipe's threaded section, then screw the pipe into the
camera's threaded receptacle.
• Sealing tape must be wrapped around the pipe's threaded part.
• The pipe receptacle thread is compatible with NPT3/4 as specified in ANSI/ASME B1.20.1 (The American
Standard Taper Pipe Threads).
3. Run the cables through the pipe, pull them out from the case opening, then secure the case to the ceiling.
Use screws with a nominal diameter of 4 mm and a length of over 25 mm. For the details of the mounting
holes, refer to p. 13. Join the pipe mounted to the camera to an extension pipe using a coupling.
Notes
• Mounting screws are not supplied with the unit. Separately prepare the screws that are strong enough to
withstand the camera load depending on the installation locations.
• The 4 camera mounting points must be waterproofed with silicone sealant.
4. As the mounting methods of the camera unit and the dome cover are the same as those when routing the
cable from the ceiling, refer to p. 14.