11
Power input terminal
Connect this terminal to 24 V AC. (50/60 Hz)
Video output terminal
(No. 1 and No. 2)
Connect to the video input terminal of the monitor,
digital video recorder, or multi-switcher.
Alarm input terminal (No. 6 –
No.
9)
Connect to the sensor with no-voltage make contact output or
the external equipment that provides an contact control output.
Camera control terminal
(No. 3 and No. 4)
Connect to the RS-485 control line from the Remote Controller
or the other camera.
1
2
3
4
5
6
7
8
9
VIDEO
GND
RS485 +
RS485 -
GND
AL1
AL2
AL3
AL4
Terminal name
[ Power supply connector ]
[ Input/output connector ]
7.1. Composite Cable Specifications
Video output cable
Power supply cable
Camera control cables
Alarm input cables
Input/output connector
Power supply connector
Input/output connector
Terminal No. Terminal name Cable color
Terminal
treatment
1
VIDEO
Yellow
BNC jack
2
GND
Shield
3
RS485 +
Green
Bare end
4
RS485 -
Blue
Bare end
5
GND
White
Bare end
6
AL1
Brown
Bare end
7
AL2
Purple
Bare end
8
AL3
Orange
Bare end
9
AL4
Gray
Bare end
Power supply connector
Terminal No. Terminal name Cable color
Terminal
treatment
1
24 V AC
Red
AC adapter
jack
2
24 V AC
Black
Note
A ground common to AL1 – AL4 (terminal No. 6 – No. 9)
is assigned to Terminal No. 5, GND terminal (white cable)
of the Input/Output terminal. Pair each of AL1 – AL4 with
Terminal No.5 for connection of the alarm input.
7.1.1. Wiring specification