5.2 Storage and scrap
Storage
If you want a long time storage of machine, please disconnect all the energy supply,
and lubricate the skidway of the clamps on the turntable to prevent oxidation.
Scrap
In accordance with the law of the metal and nonmetal for scrap processing. In the
specified place release the oil inside the machine.
6 Fault causes and solutions
Note: if you can not solve the failure, please contact the manufacturer to provide help.
We will be the first time to help you to solve the failure. Provide the relevant fault
information and fault pictures, thus the manufacturer can get rid of the trouble at the
fastest speed.
Failure phenomenon
Failure cause
Resolvent
Unidirectional rotation
of the turntable
Universal steering switch
damage
Replace universal steering
switch
Rotary table does not
rotate
Triangle damage
Replace triangle belt
Universal steering switch
damage
Replace universal steering
switch
Motor fault or line fault
Check motor and external plug
or socket
Rotary clamp opening /
closing speed is slow Muffler blockage
Clean or replace muffler
The turntable can’t lock
the rim correctly
Clamps have trouble
Replace clamps
Rotary cylinder has trouble
Replace cylinder or repair
cylinder sealing ring
W W W . T M G I N D U S T R I A L . C O M
P 1 9 / 3 7
T o l l F r e e : 1 - 8 7 7 - 7 6 1 - 2 8 1 9