background image

B

H

C

E

A

G

D

F

CAUTION

Take measures to prevent people from coming into direct contact 
with product outlets.

 Failure to do so may result in burns or other injury 

from the discharge of fluids.

When disassembling or removing the product, wait until the internal 
pressure equals atmospheric pressure and the surface of the 
product has cooled to room temperature.

 Disassembling or removing 

the product when it is hot or under pressure may lead to discharge of 
fluids, causing burns, other injuries or damage.

Be sure to use only the recommended components when repairing 
the product, and NEVER attempt to modify the product in any way.

  

Failure to observe these precautions may result in damage to the product 
or burns or other injury due to malfunction or the discharge of fluids.

Use only under conditions in which no freeze-up will occur.

 Freezing 

may damage the product, leading to fluid discharge, which may cause 
burns or other injury.

Use under conditions in which no water hammer will occur.

 The 

impact of water hammer may damage the product, leading to fluid 
discharge, which may cause burns or other injury.

2. Specifications

To avoid malfunctions, product damage, accidents or serious injury, 
install properly and DO NOT use this product outside the specification 
range. Local regulations may restrict the use of this product to below 
the conditions quoted.

CAUTION

Refer to the product nameplate for detailed specifications.

 *  Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are 

PRESSURE SHELL DESIGN CONDITIONS, 

NOT 

OPERATING CONDITIONS.

** "Valve No." is displayed for products with options. This item is omitted from the 

nameplate when there are no options.

Minimum Operating Pressure: 0.8 MPaG (115 psig) (HR80A); 1.6 MPaG (230 psig) (HR150A, HR260A)
Maximum Allowable Back Pressure: 50% of inlet pressure

A Model

B Nominal Diameter

C Maximum Allowable Pressure*

D Maximum Allowable Temperature* TMA

E Maximum Operating Pressure

F Maximum Operating Temperature TMO

G Production Lot No.

H Valve No.**

Содержание PowerDyne HR150A

Страница 1: ...eserved 881 Nagasuna Noguchi Kakogawa Hyogo 675 8511 Japan Manufacturer Tel 81 0 79 422 1122 Fax 81 0 79 422 0112 THERMODYNAMIC STEAM TRAPS HR A SERIES HR150A HR260A HR80A INSTRUCTION MANUAL Keep this manual in a safe place for future reference ...

Страница 2: ...ed to indicate the degree of urgency and the scale of potential damage and danger DANGER WARNING and CAUTION The three types of cautionary items above are very important for safety be sure to observe all of them as they relate to installation use maintenance and repair Furthermore TLV accepts no responsibility for any accidents or damage occurring as a result of failure to observe these precaution...

Страница 3: ...hich may cause burns or other injury Use under conditions in which no water hammer will occur The impact of water hammer may damage the product leading to fluid discharge which may cause burns or other injury 2 Specifications To avoid malfunctions product damage accidents or serious injury install properly and DO NOT use this product outside the specification range Local regulations may restrict t...

Страница 4: ...ption No 1 2 3 4 5 6 7 8 9 10 Body Cover Module Valve Seat Disc Air Vent Ring Disc Holder Ring Module Gasket large Module Gasket small Screen Cover Bolt No 11 12 13 14 15 16 17 18 19 Nameplate not shown Cap Set Screw not shown Guide Pin Flange Cover Nut Hexagon Nut Eye Nut Spacer M R M R M Maintenance Kit R Repair Kit ...

Страница 5: ... models 4 Proper Installation Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel Take measures to prevent people from coming into direct contact with product outlets Install for use under conditions in which no freeze up will occur Install for use under conditions in which no water hammer will occ...

Страница 6: ...m may be seen A small amount of flash steam may be visible after the discharge Blocked Discharge Impossible No condensate is discharged The trap is quiet and makes no noise The surface temperature of the trap is low Blowing Live steam continually flows from the outlet and there is a continuous metallic sound Steam Leakage Live steam is discharged through the trap outlet together with condensate ac...

Страница 7: ...without bending as it will not return to its proper shape Remove from the body Remove the gasket and clean the sealing surfaces Be careful not to bend the screen Adjust length of spacer if necessary HR150A HR260A Tighten bolts or nuts at diagonal position sequentially after having applied antiseize to the threads and threaded bolt holes It is recommended to use new bolts and nuts for the assembly ...

Страница 8: ...rect piping Trap capacity is insufficient Change to trap of suitable capacity Trap is being used below minimum operating pressure Use within pressure range Differential pressure is low Study inlet outlet pressure including rise in outlet pipe Air vent ring bimetal or disc holder ring is broken obstructing valve closure HR80A Replace air vent ring or disc holder ring HR80A Valve chattering Leakage ...

Страница 9: ...rlier of i three 3 years after delivery of Products to the first end user in the case of sealed SST Series Products for use in steam pressure service up to 650 psig ii two 2 years after delivery of Products to the first end user in the case of PowerTrap units or iii one 1 year after delivery of Products to the first end user in the case of all other Products Notwithstanding the foregoing asserting...

Страница 10: ...EREBY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE CANNOT BE EXCLUDED SUCH DAMAGES ARE EXPRESSLY LIMITED IN AMOUNT TO THE PURCHASE PRICE OF THE DEFECTIVE PRODUCT THIS EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES AND THE PROVISION OF THIS WARRANTY LIMITING REMEDIES HEREUNDER TO REPLACEMENT ARE INDEPENDENT PROVISIONS AND ANY DETERMINATION THAT THE LIM...

Страница 11: ...10 ...

Страница 12: ...Printed on recycled paper Tel 81 0 79 422 1122 Fax 81 0 79 422 0112 Rev 10 2021 M PAC 65339 a 881 Nagasuna Noguchi Kakogawa Hyogo 675 8511 Japan Manufacturer ...