Electronic failure
Maintenance required!
1. Do not perform reset
2. Contact TLV
M
Warning
350
Pre-amplifier
defective
Change pre-amplifier
F
Alarm
1)
351
Pre-amplifier
defective
Change pre-amplifier
F
Alarm
370
Pre-amplifier
defective
1. Check plug connections
2. Check cable connection of
remote version
3. Change pre-amplifier or main
electronic module
F
Alarm
371
Temperature
sensor defective
1. Check plug connections
2. Change pre-amplifier
3. Change DSC sensor
M
Warning
1)
Diagnostic of configuration
410
Data transfer
1. Check connection
2. Retry data transfer
F
Alarm
412
Processing
download
Download active, please wait
C
Warning
431
Trim 1 to 2
Carry out trim
C
Warning
437
Configuration
incompatible
1. Restart device
2. Contact TLV
F
Alarm
438
Dataset
1. Check data set file
2. Check device configuration
3. Up- and download new
configuration
M
Warning
441
Current output
1 to 2
1. Check process
2. Check current output settings
S
Warning
1)
442
Frequency output
1. Check process
2. Check frequency output settings
S
Warning
1)
443
Pulse output
1. Check process
2. Check pulse output settings
S
Warning
1)
444
Current input 1
1. Check process
2. Check current input settings
S
Warning
1)
453
Flow override
Deactivate flow override
C
Warning
484
Simulation failure
mode
Deactivate simulation
C
Alarm
485
Simulation
measured variable
Deactivate simulation
C
Warning
486
Simulation current
input 1
Deactivate simulation
C
Warning
491
Simulation current
output 1 to 2
Deactivate simulation
C
Warning
492
Simulation
frequency output
Deactivate simulation frequency
output
C
Warning
493
Simulation pulse
output
Deactivate simulation pulse output
C
Warning
494
Switch output
simulation
Deactivate simulation switch
output
C
Warning
495
Simulation
diagnostic event
Deactivate simulation
C
Warning
538
Flow computer
configuration
incorrect
Check input value (pressure,
temperature)
S
Warning
539
Flow computer
configuration
incorrect
1. Check input value (pressure,
temperature)
2. Check allowed values of the
medium properties
S
Alarm
540
Flow computer
configuration
incorrect
Check entered reference value
using the document Operating
Instructions
S
Warning
570
Inverted data heat
Check configuration of mounting
location (parameter Installation
direction)
F
Alarm