background image

24

Fluid Section 660HPX

ITEM NO    PART NO   DESCRIPTION                   QTY

300

700-735 Crank & Slide 

Connecting Rod Assy.

1

301

730-508 Retainer

1

302

700-587 Upper Guide

1

304

700-603 Upper Seal

1

305

730-505 Pump Housing

1

306

700-678 Head Cap Screw

2

307

700-601 Lower Seal 

2

308

730-506 Piston Rod

1

309

762-111 Seal

1

310

762-135 Upper Cage

1

311

762-144 Outlet Valve Ball

1

312

762-073 Outlet Valve Housing

1

313

762-134 Seat 1

314

762-057 O-Ring

1

315

730-515 Piston Assembly

1

317

730-509 Bushing

1

318

700-821 Seal

1

319

730-510 Cage

1

320

762-145 Ball

1

321

762-137 Inlet Valve Seat

1

322

762-058 O-Ring

1

323

730-507 Foot Valve Housing 

1

325

730-520 Foot Valve Assembly

1

347

762-202 Packing Tool

1

331

700-211 Pump Syphon Tube

1

332*

700-201 O-Ring (Viton)

1

335

700 213  Pump Syphon Tube Assy. 1
730-401 Repacking Kit: 

1

Includes #302, 304, 307, 311,
318, 309, 320 

(700-203 Packing Grease and 
700-793 Piston Guide Tool
also included)

391

700-804 Gasket

1

392

490-109 Fitting

1

350

730-501 Fluid Section Complete

(#301-305, 307-323) 

1

*

700-024 Optional Urethane O-Ring 1

Syphon Assembly

ITEM NO    PART NO   DESCRIPTION                   QTY

340

700-206 Syphon Tube  

Assembly (#345)

1

341

700-847 Bypass Assembly

1

342

700-204 Syphon Assembly 

(Includes #341, 345)

1

343

700-742 Hose Tie Wrap

1

344

700-805 Inlet Screen

1

700-900 Optional

30 Mesh Inlet Screen

1

345

700-212 Clip

1

For High Rider

380

710-018 Syphon Down Tube

1

382

710-046 Inlet Assembly

1

710-191 30 Mesh Screen

1

323

730-511 Housing

1

341

702-239 Bypass Assembly

1

755-109 Pail Hook

1

730-334 Clip Down Tube

1

765-142 Safety Plate

1

350

730-502 Fluid Section Complete

1

(Excludes 391, 392)

391

300

302

304

306

305

307

301

308

309
310
311
313
314
312

318

319
320
321
322

317

323

392

Install smaller

Upper Packing

(700-603)

with raised lip and O Ring 

facing down

Install larger

Lower Packings (2)

(700-601)

with raised lip and O Ring 

facing up

O RINGS

O RINGS

RAISED

LIP 

RAISED

LIP 

350

325

315

Figure 10

380
382

323

Syphon Down
Tube for use with
the High Rider
Frame Only

332

331

341

342

340

343

345

344

335

Содержание Epic 447HPX

Страница 1: ...EADING THIS MANUAL Epic 660HPX Epic 660HPX 120V Pump Only 702 405 120V Complete 702 410 230V Pump Only 702 102 CE 230V Complete 702 104 CE This manual contains important warnings and instructions Plea...

Страница 2: ...spray systems against rust corrosion and premature wear Case of 12 1 quart bottles 700 888 1 quart 700 889 Table of Contents Accessories 2 General Repairs Service 3 Maintenance Service Record 4 Warni...

Страница 3: ...t operate properly review the repair procedure to determine if everything was done correctly Refer to the Troubleshooting Charts to help identify other possible problems 4 Make certain that the servic...

Страница 4: ...e needed to validate your warranty Electric Pump Maintenance Schedule Service Record Service Performed Date Service Center Cost of Repair Months in Service Service Performed Date Service Center Cost o...

Страница 5: ...escape wire for the electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed...

Страница 6: ...nchufe de puesta a tierra podr a crear el riesgo de choque el ctrico Si es necesario reparar o re emplazar el cord n o el enchufe no conecte el alambre de puesta a tierra a ninguna de las dos terminal...

Страница 7: ...cipient en m tal lors du rin age du syst me apr s en avoir t la buse Ne vaporisez JAMAIS de substances inflammables proximit de flammes nues lampes t moin ni d aucune source d allumage Rangez l int r...

Страница 8: ...an Tool Inc spray equipment includes aluminum or galvanized components and will be affected by Halogenated Hydrocarbon solvents DO NOT USE HALOGENATED HYDROCARBONS IN TITAN EQUIPMENT EXPLANATION OF TH...

Страница 9: ...me dangereux Des tincelles peuvent galement se produire lors de branchement ou d branchement d un cordon d alimentation lectrique ou lors de la mise en marche d un moteur au gaz De telles tincelles so...

Страница 10: ...enados SOLVANTS HALOG N S D FINITION Tout solvant hydrocarbure contenant l un des l ments suivants EXEMPLES liste incomplete Pour d terminer si vos solvants ou rev tements contiennent des solvants a h...

Страница 11: ...is used by the factory for testing and protection It is necessary to flush out with mineral spirits before you begin to spray A Pour 1 2 gallon mineral spirits into a metal container and insert syphon...

Страница 12: ...from ground to roof Do not attempt to spray if wind is excessive For corners and edges split the center of the spray pattern on the corner or edge and spray vertically so that both adjoining sections...

Страница 13: ...sprayer run itself dry Step 12 Check filter on pump and gun Clean or replace Step 13 Remove spray tip from solvent clean with a soft bristle brush and store in a dry place PROBABLE CAUSE 1 Inadequate...

Страница 14: ...Pump will not maintain pressure Not enough pressure Excessive surge at spray gun Paint leaks into oil cup PROBABLE CAUSE 1 Unit unplugged or circuit fuse blown 2 Pressure setting too low 3 Brushes on...

Страница 15: ...48 with a wrench 4 Remove the On Off Switch 49 5 Install a new Switch and reattach plate and rubber boot Tighten securely 6 Reconnect the four wires to the new On Off Switch 7 Reinstall Switch Cover...

Страница 16: ...mber 1 120 700 802 Cap Nut 2 121 700 801 1 4 Carriage Bolt 2 122 702 127 Main Frame Right 1 123 710 045 Pin Axle 2 124 710 058 Washer Axle 2 125 702 048 Wheel 2 126 702 087 Spacer 2 127 700 652 Bolt 4...

Страница 17: ...X Syphon Down Tube for use with the High Rider Frame Only Replacement Labels PART NO DESCRIPTION QTY 700 418 Front Plate 1 Front Cover Label 313 175 Warning Attention Label in French 1 313 1205 Wrapar...

Страница 18: ...follow all other warnings to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1 Remove Rear Cover 131 by taking out screws...

Страница 19: ...s to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1 Follow steps 1 through 6 in Armature Replacement 2 Remove Switch cov...

Страница 20: ...er Boot 1 48 700 775 On Off Plate 1 49 700 646 Toggle Switch 1 50 765 072 Wire Switch to Starter 1 51 700 895 Fuse 15 Amp 1 52 700 714 Nut 2 53 700 785 Lock Washer 3 54 700 657 Motor Starter 1 55 761...

Страница 21: ...f Procedure outlined on Page 5 Additionally follow all other warnings to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1...

Страница 22: ...Ring 1 218 700 246 Bypass Housing 1 includes 216 217 219 700 721 005 O Ring 1 220 700 250 Bypass Valve Stem 1 222 700 244 Spring 1 224 700 248 Bypass Valve 1 Retainer 225 700 252 Bypass Cam Base 1 226...

Страница 23: ...and Bypass Cam 225 3 Using a wrench loosen Bypass Housing 218 and unscrew 4 Unscrew Bypass Retainer 224 and remove Bypass Valve Stem 220 5 Inspect ball on end of Stem 220 and O Ring 219 Clean or repl...

Страница 24: ...included 391 700 804 Gasket 1 392 490 109 Fitting 1 350 730 501 Fluid Section Complete 301 305 307 323 1 700 024 Optional Urethane O Ring 1 Syphon Assembly ITEM NO PART NO DESCRIPTION QTY 340 700 206...

Страница 25: ...2 to piston 308 and secure tightly with a wrench PACKING REPLACEMENT 13 Remove Outlet Mounting Bolt 263 from rear of pump As shown in Figure 8 page 22 14 Remove screws 306 with a 3 8 allen wrench and...

Страница 26: ...n Site Gallons Sprayed Tips Used Date Completed Quantity Sizes Job Name Foreman s Name Type of Coating Date Begun Site Gallons Sprayed Tips Used Date Completed Quantity Sizes Job Name Foreman s Name T...

Страница 27: ...igh rider frame 702 105 CE 660HPX Pump Complete With high rider frame 702 174 CE 660HPX Pump Only With low rider frame old syphon 100V EXPORT PUMPS 702 212 660HPX Pump Only With low rider frame 702 21...

Страница 28: ...UDED TO THE EXTENT PERMITTED BY LAW TITAN MAKES NO WARRANTY AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ACCESSORIES EQUIPMENT MATERIALS...

Отзывы: